I have a basic question: is it possible to configure Infiniband on a single Win7 host using a port-to-port loopback (not an internal loopback) on a single dual port card (HP OEM ConnectX-2 VPI QDR)? I'm using OFED Win 3.2 + 2.9.1000 FW)
TIA.
John Treble
Ottawa, Canada
Some details:
> flint -d mt26428_pci_cr0 query
Image type: ConnectX
FW Version: 2.9.1000
Device ID: 26428
Description: Node Port1 Port2 Sys image
GUIDs: 0002c903000cdba2 0002c903000cdba3 0002c903000cdba4 0002c903000cdba5
MACs: 000000000000 000000000001
VSD:
PSID: HP_0180000009
> ibstat
CA 'ibv_device0'
CA type:
Number of ports: 2
Firmware version: 0x2000903e8
Hardware version: 0xb0
Node GUID: 0x0002c903000cdba2
System image GUID: 0x0002c903000cdba5
Port 1:
State: Active
Physical state: LinkUp
Rate: 40
Real rate: 32.00 (QDR)
Base lid: 2
LMC: 0
SM lid: 2
Capability mask: 0x90580000
Port GUID: 0x0002c903000cdba3
Port 2:
State: Active
Physical state: LinkUp
Rate: 40
Real rate: 32.00 (QDR)
Base lid: 1
LMC: 0
SM lid: 2
Capability mask: 0x90580000
Port GUID: 0x0002c903000cdba4